Connectorized PLC Splitters

Product Overview

NetSource’s Connectorized PLC Splitters are used for inside plant and central office applications where connectorized outputs are required. The input fiber is spliced, while the pre-terminated outputs provide connector access in trays or panels. These splitters support fiber-to-the-home (FTTH) and other access deployments and meet GR-1209 and GR-1221 optical performance requirements.
  • Splitter Configurations: 1×2, 1×4, 1×8, 1×12, 1×16, 1×32, and 1×64 
  • Operating Wavelength: 1260–1650 nm 
  • Splitter Type: Planar Lightwave Circuit (PLC) 
  • Termination: Pre-terminated with SC or LC connectors with UPC or APC polish
  • Fiber Type: Single-mode G.657A2
  • Input/Output: 900µm, 2mm, or 3mm
  • Standard Fiber Lengths: Up to 2M (6.56ft), custom lengths available upon request
  • Operating Temperature: -40°C to 85°C (-40°F to 185°F) 
  •  Storage Temperature: -40°C to 85°C (-40°F to 185°F) 
  • Fiber Protection: Shipped with protective tubing to prevent damage during handling and installation 
  • Connector Durability: Tested to 500 mating cycles to ensure long-term reliability 
  • Compliance: RoHS and REACH
  • GR-1209 and GR-1221 compliant, meeting strict environmental and optical performance standards
  • Compact design optimized for splice tray installation for efficient fiber organization
  • Reliable performance in harsh environments, suitable for ISP, central office, and high-density fiber networks
  • Connector durability tested for up to 500 mating cycles, ensuring long-term reliability

 

Part Number Chart

PLC-SP    Input Fibers    Output Fibers    Input Connector Type  Output Connector Type    Input Breakout Length  Output Breakout Length    Output Breakout OD 
    1    2    SA: SC/APC  SA: SC/APC    01: 1m (3.28ft)  01: 1m (3.28ft)    900: 900um 
        4    SC: SC/UPC  SC: SC/UPC    02: 2m (6.56ft)  02: 2m (6.56ft)    2: 2mm 
        8    LA: LC/APC  LA: LC/APC    03: .3m (1ft)  03: .3m (1ft)    3: 3mm 
        16    LC: LC/UPC  LC: LC/UPC    05: .5m (1.64ft)  05: .5m (1.64ft)     
        32    X: Bare (250um)      15: 1.5m (5ft)  15: 1.5m (5ft)     
        64    Y: Bare (900um)             

Notes : add R for reverse Pull (Pull from the Terminal end)
Lengths over 950ft on a reel


Insertion Loss Chart

Parameter  1×2  1×4  1×8  1×16  1×32  1×64 
Working Wavelength  1260-1650 
Fiber Type  G657A1 or Customized 
Insertion Loss (dB)  3.8  7.1  10.2  13.5  16.8  20.2 
Uniformity (dB)  ≤0.4  ≤0.5  ≤0.8  ≤1.0  ≤1.5  ≤1.8 
Polarization Dependent Loss (dB)  ≤0.25  ≤0.25  ≤0.25  ≤0.3  ≤0.3  ≤0.35 
Return Loss (dB)  ≤55 
Directionality (dB)  ≤55 
Fiber Length (dB)  1.0 or Customized 
Temperature Stability   -40°C to 85°C (≤0.5) 
Working Temperature  -40°C to 85°C 
Storage Temperature  -40° to 85°C 
Maximum Power (mW)  300 
Scroll to Top